The Tornado, Pollution Control Work Bench from Media Blast, is a simple, well designed, down draft work bench used for the control of almost all types of nuisance dusts that can result from operations involving grinding, sanding, deburring and more. These units are totally self-contained and include 220 or 440 square feet of replaceable filter cartridge that carry a filter certification of 99.97% on .5 micron particle size. No Special Electrical or special ducting is required and all units include a blower silencer to allow air discharge back into the area where the bench is located. This prevents loss of heated or cooled air when working in smaller work spaces.
Media Blast’s Pollution Control Benches are portable, compact and cost effective for the collection of all types of nuisance dusts. Designed to create up to 500 feet per minute of down draft tabletop velocity, the Tornado creates better, balanced air flow, over the entire top work surface of the bench by using a special plenum design below the operator work grate. You can also operate this unit without the air-flow on, making this a space saving solution (when limited floor space is an issue), by creating a lighted work bench that can replace any existing work table.
All models include the 700 cfm, 120 volt blower, for quick easy machine set-up. The blower, using the open top with the air directional back and sides, all come standard and they are a good combination for lighter, slower, operations that create dust. An Optional larger 1100 cfm 3 phase blower can be added as an upgrade for tougher applications that require more bench air movement or a larger work surface area. Don’t confuse air quantity with quality! Media Blast uses a pressure blower that pulls air longer, at higher suction ratings. This design keeps the dust filters in operation longer. Extremely high air-flow rates often, have much lower suction, this results in shorter air-flow times which make filter cleaning or replacement necessary sooner.
A vacuum blower moves very little air quantity and is a poor blower for dust collection but, it has massive amounts of suction. Something like a floor fan is a blower that moves huge quantities of air but, moves almost nothing when a duct is attached that requires suction. Having the right blower suction, measured in Static Pressure Inches Of, and the right air-flow quantity, is very important. The Tornado line of equipment uses intelligent bench design, with the right air-flow and suction ratios to create simple bench operation with no maintenance and longer filter life. The optional Enclosed Top can be added to help contain really tough jobs that create faster dust amounts. All units include fluorescent lighting; open top assembly with air directing back and side panels, fiberglass bar grates, cartridge filtration and a dust access door with a dust removal pan assembly. Clean up problem areas while you protect the operator's environment and install a Media Blast Tornado today! Available in sit-down ERGO and stand-up models.
Almost all dust producing operations require the addition of some kind of operator protection. This can be as simple as an operator filter mask or it might require a permit to operate, that insures safety of operation, when collecting material that can be harmful and or a potential fire or explosion hazard requiring a stainless steel wet scrubber costing tens of thousands of dollars. Permit applications will indicate the type of unit required, the air-flow necessary and any possible design rules. The Media Blast Tornado is used for Nuisance Dust, dust that is not determined to be harmful in normal percentages. Adding a Tornado Pollution Control Work Bench will protect the operator and also protect valuable equipment in the area that may be operating using cooling heat sinks or other circuits that are affected by dust particles. The MSDS, (Material Safety Data Sheet), is a good place to start when deciding about the exact classification of the dust you are considering collecting. Always check with your state and local regulatory agencies for exact rules and regulations.
The Tornado line of pollution control benches may be the most cost effective solution to cleaning up that nuisance dust by helping to save money on costly insurance rates and creating a cleaner, healthier and happier operator work space and all without the need for any special installation requirements. The Tornado is not the solution for applications that require wet scrubbers and or materials that may have a possible potential for fire or explosion hazards. Mixing dust material is also not recommended with any equipment used to collect dust unless the equipment is located in specific areas using specific equipment safety features. If the dust is considered “Nuisance” and does not require a permit for collection, the Tornado is a low cost way to clean up the area and protect the operator and any surrounding equipment.
Building a Tornado:
- Select standard open top or optional enclosed top (use open top for slow free floating dust, use enclosed for Accelerated dust)
- Select operation (stand-up or sit-down model) not all bench sizes are available in sit-down models.
- Select work surface size (the smaller the bench and the larger the blower the better the collection)
- 700 CFM 120V Blower and Silencer standard or…..
- Upgrade to Optional 1100 CFM High Voltage Blower
All Tornado units are available as a work station only, "Downdraft Workstation", models, for connection to central dust collector or wet scrubber systems. The Tornado Work Bench has the internal dust collector and blower assembly removed and replaced with an internal hopper assembly that includes a customer specified dust outlet attachment ring. This design eliminates any standing dust and the directional hopper is used to create the uniform air-flow at the operator work grates.
NOTE: Because of the potential fire or explosion hazards, the Tornado Pollution Control Work Benches are not to be used for welding applications or applications such as grinding or sanding of aluminum, titanium, magnesium or other explosive dust. These applications require permits for operation and must be equipped with wet dust collection or what is often termed as wet scrubber systems. Always check the material MSDS for changes in dust collection requirements. Always check with your state and local regulatory agencies for exact rules and regulations.
If you think the solution to your dust problem is the Tornado Pollution Control Work Bench, the machine cost will be low and the dust collection results high. Adding a Tornado can also save on the uncomfortable operator filter masks!
The Standard Features below are included on every Tornado
Pollution Control Bench. The Other Available Features can be added at additional
cost. Any option marked with a •• is available as bolt-on and can be added
to house inventory prior to machine shipment. The other options listed are
available but require custom machine work order and may increase machine delivery
time.
Standard Features:
- 3/4 HP, 700 CFM/120v/1 phase/60 hz. Blower and Silencer
- 14 & 12 Gauge CRS Construction
- Catalyst Paint
- Toe Kick
- Fiberglass Bar Grating
- 120 Volt Operation
- Single Power Source (high-voltage units)
- Fluorescent Lighting (dust tight enclosure)
- 300-500 table top velocity
- Cartridge Access Door
- Replaceable Filter Cartridge(s)
- Exhaust Blower Silencer
- Removable Dust Storage Pan
Other Available Features:
- Steel Bar Grates ••
- Steel Bar Grates (rubber dipped) ••
- Laminated Safety Glass Full View Window (enclosed top 36")
- Laminated Safety Glass Full View Window (enclosed top 48")
- Laminated Safety Glass Full View Window (enclosed top 60")
- Steel View Panel w/ Safety Glass View Window
- Hinged Wing Panels (open top only)
- HEPA After Filtration (99.95% efficient @ 0.3 micron)
- Magnahelic Gauge (requires HEPA after filtration)
- Light Perforated Metal Grate Overlay
(above bar grates) ••
- Sound Dampening (enclose top only)
- Turntable (500 lb. capacity) 22" removable
- Turntable (500 lb. capacity) 26" removable
- Turntable Rubber Dipped
- Additional Fluorescent Light Fixture (may require transformer upgrade)
- Additional Spot Lighting
(included transform upgrade) - Special Color (matched to chip)
- Timed Reverse Pulse Cleaning (dual cartridge only)
- Touch Up Paint Kit ••
- 1100 CFM Exhaust Blower Upgrade w/ Single Power Source and Exhaust Silencer
NOTE: Standard Features are included with every model. Available Features can be added at additional cost. Available Features marked with a •• can be bolted-on to house inventory prior to machine shipment. Other Available Features require custom machine work and may increase machine delivery time.
Technical Specifications:
| Physical Specifications: | |
| Paint Specs: | Environmentally Friendly High Grade Polyurethane High Gloss Paint. Standard colors MBA Beige and High Gloss White. Custom color matches and Powder Coating available per customer supplied color sample. Call for pricing. |
Standard Model Specifications:
| MODEL | NOTE |
WORK AREA |
OVERALL DIMENSIONS |
DUST
COLLECTOR SPECIFICATIONS |
ELECTRICAL |
| Open Top Workbench (includes internal dust collector) | |||||
| PC32 Request Info |
36"W x 24"D | 52"W
x 30"D x 60"H |
Single
Cartridge, 700 CFM Blower • |
120V |
|
| PC42 Request Info |
47"W x 24"D | 65"W
x 30"D x 60"H |
Single
Cartridge, 700 CFM Blower • |
120V |
|
| PC3630 Request Info |
36"W x 30"D | 36"W
x 45"D x 60"H |
Dual Cartridge, 700 CFM Blower • |
120V |
|
| PC3644 Request Info |
Sitdown |
36"W x 44"D | 36"W
x 59"D x 60"H |
Dual Cartridge, 700 CFM Blower • |
120V |
| PC3636 Request Info |
36"W x 36"D | 36"W
x 51"D x 60"H |
Dual Cartridge, 700 CFM Blower • |
120V |
|
| PC4730 Request Info |
47"W x 30"D | 47"W
x 45"D x 60"H |
Dual Cartridge, 700 CFM Blower • |
120V |
|
| PC4744 Request Info |
Sitdown |
47"W x 44"D | 47"W
x 61"D x 60"H |
Dual Cartridge, 700 CFM Blower • |
120V |
| PC4736 Request Info |
47"W x 36"D | 47"W
x 51"D x 60"H |
Dual Cartridge, 700 CFM Blower • |
120V |
|
| PC5436 Request Info |
54"W x 36"D | 54"W
x 53"D x 60"H |
Dual Cartridge, 700 CFM Blower • |
120V |
|
| PC6044 Request Info |
Sitdown |
60"W x 44"D | 60"W
x 61"D x 60"H |
Dual Cartridge, 700 CFM Blower • |
120V |
| PC5444 Request Info |
Sitdown |
54"W x 44"D | 54"W
x 61"D x 60"H |
Dual Cartridge, 700 CFM Blower • |
120V |
| Enclosed Top Workbench (includes internal dust collector) | |||||
| PCE32 Request Info |
36"W
x 24"D |
52"W x 30"D x
60"H |
Single Cartridge, 700 CFM
Blower • |
120V |
|
| PCE42 Request Info |
47"W
x 24"D |
65"W x 30"D x
60"H |
Single Cartridge, 700 CFM
Blower • |
120V |
|
| PCE3630 Request Info |
36"W
x 30"D |
36"W x 45"D x
60"H |
Dual Cartridge, 700 CFM
Blower • |
120V |
|
| PCE3644 Request Info |
Sitdown |
36"W
x 44"D |
36"W x 59"D x
60"H |
Dual Cartridge, 700 CFM
Blower • |
120V |
| PCE3636 Request Info |
36"W
x 36"D |
36"W x 51"D x
60"H |
Dual Cartridge, 700 CFM
Blower • |
120V |
|
| PCE4730 Request Info |
47"W
x 30"D |
47"W x 45"D x
60"H |
Dual Cartridge, 700 CFM
Blower • |
120V |
|
| PCE4744 Request Info |
Sitdown |
47"W
x 44"D |
47"W x 61"D x
60"H |
Dual Cartridge, 700 CFM
Blower • |
120V |
| PCE4736 Request Info |
47"W
x 36"D |
47"W x 51"D x
60"H |
Dual Cartridge, 700 CFM
Blower • |
120V |
|
| PCE5436 Request Info |
54"W
x 36"D |
54"W x 53"D x
60"H |
Dual Cartridge, 700 CFM
Blower • |
120V |
|
| PCE6044 Request Info |
Sitdown |
60"W
x 44"D |
60"W x 61"D x
60"H |
Dual Cartridge, 700 CFM
Blower • |
120V |
| PCE5444 Request Info |
Sitdown |
54"W
x 44"D |
54"W x 61"D x
60"H |
Dual Cartridge, 700 CFM
Blower • |
120V |
| Space Saver 3024 Request Info |
Stand Up |
30"W
x 24"D |
32"W x 37"D x
63"H |
Bag Style Filter - 550
CFM Blower • |
120V |
| Open Top Work Station (includes internal directional hopper assembly, no dust collector) | |||||
| PCW32 Request Info |
36"W x 24"D | 52"W
x 24"D x 60"H |
Customer
Supplied •• |
120V |
|
| PCW42 Request Info |
47"W x 24"D | 65"W
x 24"D x 60"H |
Customer Supplied •• |
120V |
|
| PCW3630 Request Info |
36"W x 30"D | 36"W
x 30"D x 60"H |
Customer Supplied •• |
120V |
|
| PCW3644 Request Info |
Sitdown |
36"W x 44"D | 36"W
x 44"D x 60"H |
Customer Supplied •• |
120V |
| PCW3636 Request Info |
36"W x 36"D | 36"W
x 36"D x 60"H |
Customer Supplied •• |
120V |
|
| PCW4730 Request Info |
47"W x 30"D | 47"W
x 30"D x 60"H |
Customer Supplied •• |
120V |
|
| PCW4744 Request Info |
Sitdown |
47"W x 44"D | 47"W
x 44"D x 60"H |
Customer Supplied •• |
120V |
| PCW4736 Request Info |
47"W x 36"D | 47"W
x 36"D x 60"H |
Customer Supplied •• |
120V |
|
| PCW5436 Request Info |
54"W x 36"D | 54"W
x 36"D x 60"H |
Customer Supplied •• |
120V |
|
| PCW6044 Request Info |
Sitdown |
60"W x 44"D | 60"W
x 44"D x 60"H |
Customer Supplied •• |
120V |
| PCW5444 Request Info |
Sitdown |
54"W x 44"D | 54"W
x 44"D x 60"H |
Customer Supplied •• |
120V |
| Enclosed Top Workstation (includes internal directional hopper assembly, no dust collector) | |||||
| PCEW32 Request Info |
36"W x 24"D |
52"W x 24"D x
60"H |
Customer Supplied •• |
120V |
|
| PCEW42 Request Info |
47"W x 24"D |
65"W x 24"D x
60"H |
Customer Supplied •• |
120V |
|
| PCEW3630 Request Info |
36"W x 30"D |
36"W x 30"D x
60"H |
Customer Supplied •• |
120V |
|
| PCEW3644 Request Info |
Sitdown |
36"W x 44"D |
36"W x 44"D x
60"H |
Customer Supplied •• |
120V |
| PCEW3636 Request Info |
36"W x 36"D |
36"W x 36"D x
60"H |
Customer Supplied •• |
120V |
|
| PCEW4730 Request Info |
47"W x 30"D |
47"W x 30"D x
60"H |
Customer Supplied •• |
120V |
|
| PCEW4744 Request Info |
Sitdown |
47"W x 44"D |
47"W x 44"D x
60"H |
Customer Supplied •• |
120V |
| PCEW4736 Request Info |
47"W x 36"D |
47"W x 36"D x
60"H |
Customer Supplied •• |
120V |
|
| PCEW5436 Request Info |
54"W x 36"D |
54"W x 36"D x
60"H |
Customer Supplied •• |
120V |
|
| PCEW6044 Request Info |
Sitdown |
60"W x 44"D |
60"W x 44"D x
60"H |
Customer Supplied •• |
120V |
| PCEW5444 Request Info |
Sitdown |
54"W
x 44"D |
54"W x 44"D x
60"H |
Customer Supplied •• |
120V |
| • NOTE: 3/4 HP – 700 CFM – 120V/single phase electrical standard blower configuration Upgrade 2 HP – 1100 CFM – 208 – 220 – 240V/single phase electrical Upgrade 2 HP – 1100 CFM – 208 – 220 – 240V/three phase electrical Upgrade 2 HP – 1100 CFM – 440 – 460 – 480V/three phase electrical |
|||||
•• NOTE: Work
Station Models do not include the internal dust collector. The
recommended conveyor duct speed is 3500 feet per minute velocity,
use the following information for hopper outlet discharge sizing
on all Work Station Models:
|
|||||